Align observation time
Record acquisition time, reception time, clock basis, and any known delay. Two messages received together may describe different physical moments. Conversely, simultaneous observations can arrive in a different order because their communication paths differ.
Matching messages within a time window is an association policy, not proof that their clocks are synchronized. The window must be justified by motion, sensor cadence, and measured timing error. A delayed camera result should not be allowed to overwrite a newer position without an explicit historical update policy.